Industrial - Current Meter, 0-20 mA

Industrial-grade (NEMA-rated enclosure). Wireless 0-20mA current meters are capable of measuring the current off another device or sensor, up to 20mA (DC), by connecting the leads of the sensor to…

Overview

Wireless 0-20mA current meters are capable of measuring the current off another device or sensor, up to 20mA (DC), by connecting the leads of the sensor to the positive and ground terminals of the device being measured. Examples of interfacing devices include, but are not limited to: Current transducers (CTs) with outputs up to 20 mA, pH sensor, dissolved oxygen sensor, pressure sensor, magnetic flow meters, velocity or acceleration sensors, industrial vibration sensors, industrial accelerometers, any kind of sensor that specifies the output is in (mA) within the range of 0 – 20.

How They Work

  1. The sensor measures interface & data using its integrated sensing element at configurable intervals.
  2. Readings are transmitted wirelessly to the UpKeep Edge gateway via the 900 MHz protocol, with Encrypt-RF security.
  3. UpKeep Edge processes incoming data in real time, comparing readings against user-defined alert thresholds.
  4. When thresholds are breached, instant notifications are sent via text, email, or phone call to designated team members.
  5. All data is logged for historical trending, compliance reporting, and predictive maintenance analysis.

Applications

  • Custom sensor integration
  • Legacy equipment connectivity
  • Process control interfacing
  • Multi-sensor data collection

Specifications

SKU MNS2-9-IN-MA2-020
Category Power & Electrical
Sensor type Interface Meters & Sensors
Dimensions 3.7 × 2.9 × 1.4 in
Weight 4.8 oz
Wireless Range Up to 1,200+ ft. (non-line-of-sight)
Battery Life Up to 10+ years (usage-dependent)
Encryption Encrypt-RF (256-bit AES)

Questions about this sensor

What does the Industrial - Current Meter, 0-20 mA measure?
Wireless 0-20mA current meters are capable of measuring the current off another device or sensor, up to 20mA (DC), by connecting the leads of the sensor to the positive and ground terminals of the device being measured. Examples of interfacing devices include, but are not limited to: Current transducers (CTs) with outputs up to 20 mA, pH sensor, dissolved oxygen sensor, pressure sensor, magnetic flow meters, velocity or acceleration sensors, industrial vibration sensors, industrial accelerometers, any kind of sensor that specifies the output is in (mA) within the range of 0 – 20.
Where is the Industrial - Current Meter, 0-20 mA typically installed?
Common placements include custom sensor integration, legacy equipment connectivity, process control interfacing. It uses a NEMA-rated industrial enclosure, so it holds up to wash-down, outdoor, and high-vibration locations.
What does it need to work?
An UpKeep Edge gateway within about 1,200 ft. One gateway supports 50 or more sensors, and readings reach UpKeep over the gateway's cellular, Ethernet, or Modbus connection.
What happens when a reading is out of range?
UpKeep opens a work order against the asset and notifies the assigned technician. You set the thresholds for each interface meters & sensor individually.