El análisis de modo y efectos de falla (FMEA) es una herramienta útil para reconocer y evaluar fallas y evitar que ocurra la falla potencial.

Duración: 2 minutes
Ryan Chan
Publicado el August 23, 2019

*Over the next few weeks, UpKeep will be releasing chapters from our upcoming publication, How Maintenance Will Revolutionize the World. Chapter 4.1 can be found here.


PHASE 2  - MAINTENANCE VS RELIABILITY

copy-of-how-maintenance-will-revolutionize-the-world-791x1024.png

STEP 1 - Understand failure modes

Failure Mode and Effects Analysis (FMEA) is a helpful tool to: (a) recognize and evaluate the potential failure(s) of an item or process and the effects of that failure, and (b) identify actions that could eliminate or reduce the likelihood of the potential failure occurring (probability of occurrence). 

The performance of an asset relates to its current ability to meet current and future demands. Assets can fail in four major ways, known as primary failure modes, which can be used to determine the most appropriate investment strategies relevant to the asset.

The four Primary Failure Modes are: Physical Mortality, Level of Service, Capacity, and Financial Efficiency.

We have included a step-by-step process below to begin assigning failure modes to your assets and make a prioritized plan as an organization. With each example, a template has been provided at the end of that step for you to follow along.

STEP 2 - Organize your assets and brainstorm failure modes in the template provided.

Think of anything that can go wrong and use the chart below of examples to help you. 

EXAMPLE:
Failure ModeDescription and DriversAssessment TechniqueManagement Strategy
Physical Mortality

Asset deterioration reduces performance below an acceptable level 

Age, Usage, Operational Stresses, Acts of Nature

Condition 

Level 1 – Staff Knowledge – Desktop ‘Delphi’ 

Level 2 – Intermediate level Physical Inspection (See Appendix A) 

Level 3 – Advanced Physical Testing and inspection

Renewal, O&M Optimization
Capacity

Demand exceeds design capacity 

Growth and System Expansion

Capacity 

Level 1 – Staff Knowledge – Desktop ‘Delphi’ 

Level 2 – Desktop Capacity Modeling 

Level 3 – Capacity Modeling with Field Data

Redesign
Level of Service

Functional and Reliability requirements exceed design capability 

 

Regulations, Quality, Safety, Service, Noise, Odor 

Function 

Level 1 – Staff Knowledge – Desktop ‘Delphi’ 

Level 2 – Process Assessment 

Level 3 – Strategic Planning 

Reliability 

Level 1 – Staff Knowledge – Desktop ‘Delphi’ 

Level 2 – Desktop Analysis

Level 3 – Work Order History (MTBF)

Redesign, O&M Optimization
Financial Efficiency

Cost of Operation exceeds feasible alternatives 

New Technology, Wear, Spare Parts

Efficiency 

Level 1 – Staff Knowledge – Desktop ‘Delphi’ 

Level 2 – Desktop LCCA (Estimated Data) 

Level 3 – LCCA with Field Data

Replace
TEMPLATE:
Asset NamePossible Failure Modes

 

 

 

 

 

 

 

 

 

 

STEP 3 - Rate the likelihood of occurrence of each failure mode based on the below rubric.

Add your rating to your template. 

EXAMPLE:
chapter-4-2-image-1.png
Likelihood of OccurrenceCriteria: Possible Failure Rates/Probability of FailureRating
Extremely HighFailure rate of less than 5 FPMH/Probability of Failure During Mission <0.210
Very High Failure rate of less than 2 FPMH/Probability of Failure During 9
High Failure rate of less than 1 FPMH/Probability of Failure During Mission <0.058
Moderately HighFailure rate of less than 200 FIT/Probability of Failure During Mission <0.017
ModerateFailure rate of less than 100 FIT/Probability of Failure During Mission <0.0056
Moderately Low Failure rate of less than 20 FIT/Probability of Failure During Mission <0.0015
Low Failure rate of less than 10 FIT/Probability of Failure During Mission <0.00054
Very Low Failure rate of less than 2 FIT/Probability of Failure During Mission <0.00013
Extremely Low Failure rate of less than 1 FIT/Probability of Failure During Mission <0.000052
RemoteFailure rate of less than 0.2 FIT/Probability of Failure During Mission <0.000011
 
TEMPLATE:
Asset NamePossible Failure ModesLikelihood

 

 

  

 

 

  

 

 

  

 

STEP 4 - Rate the severity of each failure mode for your assets using the below rubric as a guide.

Add your severity rating to your template.

[Image not migrated]

EXAMPLE:

Severity

Criteria

Rating

Extremely High

Catastrophic: Serious injury or loss of life.

10

Very High

 

9

High

 

8

Moderately High

 

7

Moderate

 

6

Moderately Low

 

5

Low

 

4

Very Low

 

3

Extremely Low

 

2

Remote

Minor: No loss of downtime.

1


TEMPLATE:

Asset Name

Possible Failure Modes

Likelihood

Severity

 

 

   

 

 

   

 

 

   

STEP 5 - Assign a priority number to each asset.

To do this, multiple your severity rating x your likelihood of occurrence rating. Here, you can see how our example results in clear priority numbers. Add your priority numbers in your template.

chapter-4-2-image-3.png
EXAMPLE:

Asset Name

Asset Category

Primary Failure mode

Likelihood of occurrence

Severity

Risk Priority Number (Severity * Occurrence)

HVAC - Air Filtration

HVAC

Outside air filtration blockage. (normal & abnormal events)

3

6

18

HVAC - Air Filtration

HVAC

 

10

7

70

Template:

Asset NamePossible Failure ModesLikelihoodSeverityRisk Priority Number (Severity * Occurrence)

 

 

    

 

 

    

 

 

    

STEP 6 - Understand mitigation by risk priority.

Reorganize your template so that you are now viewing your assets from most important to least. Now, brainstorm a plan of actions or mitigations you can take to avoid failure in the first place.

EXAMPLE:

Asset Name

Asset Category

Primary Failure mode

Severity

Likelihood of occurrence

Risk Priority Number (Severity * Occurrence)

Mitigation / Action Plan

HVAC - Air Filtration

HVAC

Outside air filtration blockage. (normal & abnormal events)

6 due to bio containment

3

18

Duplicate outside air filtration

Predictive fouling rate

HVAC - Air Filtration

HVAC

Fan failure

9 due to loss of control of critical parameters.

Loss of pressure

6

54

Standby fans

Vibration monitor

TEMPLATE:

Asset Name

Possible Failure Modes

Likelihood

Severity

Risk Priority Number (Severity * Occurrence)

 

 

    

 

 

    

 

 

    

STEP 7 - Revisit your plan every Quarter.

 